Product Citations: 2

Powered by

Superparamagnetic bead interactions with functionalized surfaces characterized by an immunomicroarray.

In Acta Biomaterialia on 1 October 2010 by Skottrup, P. D., Hansen, M. F., et al.

Magneto-resistive sensors capable of detecting superparamagnetic micro-/nano-sized beads are promising alternatives to standard diagnostic assays based on absorbance or fluorescence and streptavidin-functionalized beads are widely used as an integral part of these sensors. Here we have developed an immunomicroarray for systematic studies of the binding properties of 10 different micro-/nano-sized streptavidin-functionalized beads to a biotin substrate immobilized on SiO(2) with or without surface modification. SiO(2) surface cleaning, immobilized substrate concentration and surface blocking conditions were optimized. Polyethylene glycol-based surfaces with different end groups on the anchor molecule, 2,4,6-trichloro-1,3,5-triazine (TsT), were synthesized and compared with the standard (3-aminopropyl)triethoxysilane (APTS)/glutaraldehyde chemistry. APTS/glutaraldehyde, directly linked TsT and bare H(2)O(2)-activated SiO(2) performed better than polyethylene glycol-modified surfaces. Two beads, Masterbeads and M-280 beads, were found to give superior results compared with other bead types. Antibody/antigen interactions, illustrated by C-reactive protein, were best performed with Masterbeads. The results provide important information concerning the surface binding properties of streptavidin-functionalized beads and the immunomicroarray can be used when optimizing the performance of bead-based biosensors.
2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

A novel interdigitated capacitor based biosensor for detection of cardiovascular risk marker.

In Biosensors Bioelectronics on 15 December 2009 by Quershi, A., Gurbuz, Y., et al.

C-reactive protein (CRP) is a potential biomarker whose elevated levels in humans determine cardiovascular disease risk and inflammation. In this study, we have developed a novel capacitive biosensor for detection of CRP-antigen using capacitor with interdigitated gold (GID) electrodes on nanocrystalline diamond (NCD) surface. The NCD surface served as a dielectric layer between the gold electrodes. GID-surface was functionalized by antibodies and the immobilization was confirmed by Fourier transform spectroscopy (FT-IR) and contact angle measurements. The CRP-antigen detection was performed by capacitive/dielectric-constant measurements. The relaxation time and polarizability constants were estimated using Cole-Cole model. Our results showed that the relaxation time constant (tau) of only CRP-antibody was within 10(-16)-10(-13)s, which was increased to 10(-11)s after the incubation with CRP-antigen, suggesting that the CRP-antigen was captured by the antibodies on GID-surface. In addition, polarizability constant (m) of CRP was also increased upon incubation with increasing concentration of CRP-antigen. Our results showed that the response of GID-NCD-based capacitive biosensor for CRP-antigen was dependent on both concentration (25-800ng/ml) as well as frequency (50-350MHz). Furthermore, using optimized conditions, the GID-NCD based capacitive biosensor developed in this study can potentially be used for detection of elevated levels of protein risk markers in suspected subjects for early diagnosis of disease.

View this product on CiteAb