Product Citations: 10

Diagnosis of non-tuberculous mycobacterial (NTM) infection is difficult due to low sensitivity and time-consuming laboratory tests. Current serological assays fail in tropical countries due to high antibody background. This study aimed to investigate an appropriate method for detecting anti-glycopeptidolipid (GPL)-core antibodies to diagnose NTM infection in Thailand. Heparinized plasma samples were collected from 20 patients with NTM-pulmonary disease (NTM-PD) and 22 patients with disseminated NTM (dNTM) for antibody detection by ELISA. The results were compared with those from patients with tuberculosis, other bacterial pulmonary infections and healthy controls. Among the different antibody isotypes, anti-GPL-core IgA exhibited the highest suitability. Therefore, anti-GPL-core IgA and its subclass IgA2 were further investigated. A significant increase in antibody levels was observed during the active infection stage, whereas NTM-PD with culture conversion at the 6-month follow-up showed reduced IgA levels. The diagnostic cut-off for IgA and IgA2 was newly defined as 1.4 and 1.0 U/ml, respectively. Using our IgA cut-off, the sensitivity and specificity for diagnosing NTM-PD were 77.3% and 81.4%, respectively. The new IgA cut-off demonstrated significantly improved specificity compared to the manufacturer's cut-off. Thus, serological detection of anti-GPL-core IgA, with a cut-off of 1.4 U/ml, can be a valuable tool for supporting NTM diagnosis in Thailand.
© 2023. The Author(s).

We assessed the humoral immune responses to a COVID-19 vaccine in a well-controlled rhesus macaque model compared to humans immunized with two mRNA vaccines over several months post-second dose. The plasma IgG levels against seven coronaviruses (including SARS-CoV-2) and antibody subtypes (IgG 1-4 and IgM) against SARS-CoV-2 were evaluated using multiplex assays. The neutralization capacity of plasma antibodies against the original SAR-CoV-2 isolate and nine variants was evaluated in vaccinated humans and non-human primates. Immunization of macaques and humans with SARS-CoV-2 vaccines induced a robust neutralizing antibody response. In non-SIV-infected adult macaques immunized with an adenoviral vector expressing S-RBD (n = 7) or N protein (n = 3), elevated levels of IgG and neutralizing antibodies were detected 2 weeks post-second dose. Immune responses to the S-RBD vaccine in SIV-infected adult macaques (n = 2) were similar to the non-SIV-infected animals. Adult humans immunized with Pfizer (n = 35) or Moderna (n = 18) vaccines developed IgG and neutralizing antibodies at 4 weeks post-second dose. In both vaccine groups, IgG 1 was the predominant subtype, followed by IgG 3. The IgG levels, including total and IgG 1,2,3 elicited by the Moderna vaccine, were significantly higher than the corresponding levels elicited by the Pfizer vaccine at 4 weeks post-second dose. A significant correlation was observed between the plasma total IgG antibody levels and neutralization titers in both macaques and humans. Furthermore, broad-spectrum neutralization antibodies against several variants of SARS-CoV-2 were detected in the plasma of both macaques and humans after two vaccinations.
Copyright: © 2023 Ravindran et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

  • COVID-19
  • Immunology and Microbiology

Dynamics of Temporal Immune Responses in Nonhuman Primates and Humans Immunized with COVID-19 Vaccines

Preprint on Research Square on 14 September 2022 by Khan, I., Ravindran, R., et al.

We assessed the humoral immune responses to a COVID-19 vaccine in a well-controlled rhesus macaque model in comparison to humans immunized with two mRNA vaccines over several months post-second dose. The plasma IgG levels against seven coronaviruses (including SARS-CoV-2) and antibody subtypes (IgG1-4 and IgM) against SARS-CoV-2 were evaluated using multiplex assays. The neutralization capacity of plasma antibodies against original SAR-CoV-2 isolate and nine variants was evaluated in vaccinated humans and non-human primates. Immunization of macaques and humans with SARS-CoV-2 vaccines induced a robust neutralizing antibody response. In non-SIV infected adult macaques immunized with an adenoviral vector expressing S-RBD (n = 7) or N protein (n = 3), elevated levels of IgG and neutralizing antibodies were detected 2 weeks post-second dose. Immune responses to the S-RBD vaccine in SIV-infected adult macaques (n = 2) were similar to the non-SIV-infected animals. Adult humans immunized with Pfizer (n = 35) or Moderna (n = 18) vaccines developed IgG and neutralizing antibodies at 4 weeks post-second dose. In both vaccine groups, IgG 1 was the predominant subtype, followed by IgG 3. The IgG levels, including total and IgG1,2,3 elicited by Moderna vaccine, were significantly higher than the corresponding levels elicited by the Pfizer vaccine at 4 weeks post-second dose. A significant correlation was observed between the plasma total IgG antibody levels and neutralization titers in both macaques and humans. Furthermore, broad-spectrum neutralization antibodies against several variants of SARS-CoV-2 were detected in the plasma of both macaques and humans after two vaccinations.

  • COVID-19
  • Immunology and Microbiology

Detection of Neutralizing Anti-Type 1 Interferon Autoantibodies.

In Current Protocols on 1 August 2022 by Shaw, E. R., Rosen, L. B., et al.

Autoantibodies (autoAbs) that neutralize type 1 interferons (T1IFNs) are a major risk factor associated with developing critical COVID-19 disease and are most commonly found in individuals over age 70 and in patients with genetic or acquired thymic defects. Swift identification of autoAb-positive individuals may allow targeted interventions to prevent critical COVID-19 disease. Herein, we provide a workflow and protocols aimed at rapidly identifying individuals who are autoAb positive from a large cohort. Basic Protocol 1 describes a multiplex particle-based assay to screen large cohorts of individuals for binding levels of anti-T1IFN autoAbs, and Basic Protocol 2 describes a functional assay to test if autoAbs in patient plasma can block T1IFN-induced JAK/STAT signaling. © Published 2022. This article is a U.S. Government work and is in the public domain in the USA. Basic Protocol 1: Multiplex particle-based bead assay to screen for binding levels of anti-type 1 interferon autoantibodies Alternate Protocol: Multiplex particle-based bead assay to screen for binding levels of anti-type 1 interferon immunoglobulin subtypes and isotypes Support Protocol: Coupling type 1 interferons (IFN-α, IFN-β, and IFN-ω) to magnetic beads Basic Protocol 2: pSTAT1 functional assay to test for neutralization activity of anti-type 1 interferon autoantibodies.
© Published 2022. This article is a U.S. Government work and is in the public domain in the USA.

  • Homo sapiens (Human)

Immune response dynamics in COVID-19 patients to SARS-CoV-2 and other human coronaviruses.

In PLoS ONE on 10 July 2021 by Ravindran, R., McReynolds, C., et al.

COVID-19 serological test must have high sensitivity as well as specificity to rule out cross-reactivity with common coronaviruses (HCoVs). We have developed a quantitative multiplex test, measuring antibodies against spike (S) proteins of SARS-CoV-2, SARS-CoV, MERS-CoV, and common human coronavirus strains (229E, NL63, OC43, HKU1), and nucleocapsid (N) protein of SARS-CoV viruses. Receptor binding domain of S protein of SARS-CoV-2 (S-RBD), and N protein, demonstrated sensitivity (94% and 92.5%, respectively) in COVID-19 patients (n = 53), with 98% specificity in non-COVID-19 respiratory-disease (n = 98), and healthy-controls (n = 129). Anti S-RBD and N antibodies appeared five to ten days post-onset of symptoms, peaking at approximately four weeks. The appearance of IgG and IgM coincided while IgG subtypes, IgG1 and IgG3 appeared soon after the total IgG; IgG2 and IgG4 remained undetectable. Several inflammatory cytokines/chemokines were found to be elevated in many COVID-19 patients (e.g., Eotaxin, Gro-α, CXCL-10 (IP-10), RANTES (CCL5), IL-2Rα, MCP-1, and SCGF-b); CXCL-10 was elevated in all. In contrast to antibody titers, levels of CXCL-10 decreased with the improvement in patient health suggesting it as a candidate for disease resolution. Importantly, anti-N antibodies appear before S-RBD and differentiate between vaccinated and infected people-current vaccines (and several in the pipeline) are S protein-based.

  • COVID-19
  • Immunology and Microbiology
View this product on CiteAb