Product Citations: 3

The presence of T regulatory (Treg) cells in the tumor microenvironment is associated with poor prognosis and resistance to therapies aimed at reactivating anti-tumor immune responses. Therefore, depletion of tumor-infiltrating Tregs is a potential approach to overcome resistance to immunotherapy. However, identifying Treg-specific targets to drive such selective depletion is challenging. CCR8 has recently emerged as one of these potential targets. Here, we describe GS-1811, a novel therapeutic monoclonal antibody that specifically binds to human CCR8 and is designed to selectively deplete tumor-infiltrating Tregs. We validate previous findings showing restricted expression of CCR8 on tumor Tregs, and precisely quantify CCR8 receptor densities on tumor and normal tissue T cell subsets, demonstrating a window for selective depletion of Tregs in the tumor. Importantly, we show that GS-1811 depleting activity is limited to cells expressing CCR8 at levels comparable to tumor-infiltrating Tregs. Targeting CCR8 in mouse tumor models results in robust anti-tumor efficacy, which is dependent on Treg depleting activity, and synergizes with PD-1 inhibition to promote anti-tumor responses in PD-1 resistant models. Our data support clinical development of GS-1811 to target CCR8 in cancer and drive tumor Treg depletion in order to promote anti-tumor immunity.
© 2022 Jounce Therapeutics, Inc. Published with license by Taylor & Francis Group, LLC.

  • FC/FACS
  • Cancer Research

Guidelines for the use of flow cytometry and cell sorting in immunological studies (third edition).

In European Journal of Immunology on 1 December 2021 by Cossarizza, A., Chang, H. D., et al.

The third edition of Flow Cytometry Guidelines provides the key aspects to consider when performing flow cytometry experiments and includes comprehensive sections describing phenotypes and functional assays of all major human and murine immune cell subsets. Notably, the Guidelines contain helpful tables highlighting phenotypes and key differences between human and murine cells. Another useful feature of this edition is the flow cytometry analysis of clinical samples with examples of flow cytometry applications in the context of autoimmune diseases, cancers as well as acute and chronic infectious diseases. Furthermore, there are sections detailing tips, tricks and pitfalls to avoid. All sections are written and peer-reviewed by leading flow cytometry experts and immunologists, making this edition an essential and state-of-the-art handbook for basic and clinical researchers.
© 2021 Wiley-VCH GmbH.

  • FC/FACS
  • Mus musculus (House mouse)
  • Immunology and Microbiology

The interrogation of single cells is revolutionizing biology, especially our understanding of the immune system. Flow cytometry is still one of the most versatile and high-throughput approaches for single-cell analysis, and its capability has been recently extended to detect up to 28 colors, thus approaching the utility of cytometry by time of flight (CyTOF). However, flow cytometry suffers from autofluorescence and spreading error (SE) generated by errors in the measurement of photons mainly at red and far-red wavelengths, which limit barcoding and the detection of dim markers. Consequently, development of 28-color fluorescent antibody panels for flow cytometry is laborious and time consuming. Here, we describe the steps that are required to successfully achieve 28-color measurement capability. To do this, we provide a reference map of the fluorescence spreading errors in the 28-color space to simplify panel design and predict the success of fluorescent antibody combinations. Finally, we provide detailed instructions for the computational analysis of such complex data by existing, popular algorithms (PhenoGraph and FlowSOM). We exemplify our approach by designing a high-dimensional panel to characterize the immune system, but we anticipate that our approach can be used to design any high-dimensional flow cytometry panel of choice. The full protocol takes a few days to complete, depending on the time spent on panel design and data analysis.

View this product on CiteAb